4300 Storefront

Features

  • Thermal broken performance
  • Options to exterior glazing or interior glazing
  • Rain screen system
  • Hidden screws design
  • EPDM seal gaskets on exterior and interior
  • Setting for double glazing and single sheet glazing
  • Flexible to custom design and unlimited integration to standard and/or any sizes of vents and doors

Frames

  • Sight Line:   50.8mm (2″)
  • System Depth:   114.3mm (4 1/2″)
  • Thermal Break:   26.0mm (1″) polyamide

Glass

  • Double Glazed: 25.4mm (1″) IGU
  • Single Sheet Glazed: From 6mm to 10mm (From 1/4″ to 3/8″)

Specifications

Product designationClass CW-PG50
Air Leakage Resistance0.030 L/s/m(0.006 cfm/ft2) @ 75 Pa (1.57 psf) 
0.076 L/s/m(0.015cfm/ft2) @ 300 Pa (6.27 psf)
Water Penetration Resistance720 Pa (15.04 psf)
Uniform Load Deflection 2400 Pa (50.13 psf)
Uniform Load Structural 2400 Pa (50.13 psf)
Forced-entry ResistanceF10 rating
U-factor See U-factor Table  

4300 Storefront Data

For CAD details, test reports, fabrication manual, and glazing manual, please contact your sales representatives.